//===- XRayInstrumentation.cpp - Adds XRay instrumentation to functions. --===// // // Part of the LLVM Project, under the Apache License v2.0 with LLVM Exceptions. // See https://llvm.org/LICENSE.txt for license information. // SPDX-License-Identifier: Apache-2.0 WITH LLVM-exception // //===----------------------------------------------------------------------===// // // This file implements a MachineFunctionPass that inserts the appropriate // XRay instrumentation instructions. We look for XRay-specific attributes // on the function to determine whether we should insert the replacement // operations. // //===---------------------------------------------------------------------===// #include "llvm/ADT/STLExtras.h" #include "llvm/ADT/SmallVector.h" #include "llvm/ADT/Triple.h" #include "llvm/CodeGen/MachineBasicBlock.h" #include "llvm/CodeGen/MachineDominators.h" #include "llvm/CodeGen/MachineFunction.h" #include "llvm/CodeGen/MachineFunctionPass.h" #include "llvm/CodeGen/MachineInstrBuilder.h" #include "llvm/CodeGen/MachineLoopInfo.h" #include "llvm/CodeGen/TargetInstrInfo.h" #include "llvm/CodeGen/TargetSubtargetInfo.h" #include "llvm/IR/Attributes.h" #include "llvm/IR/Function.h" #include "llvm/InitializePasses.h" #include "llvm/Pass.h" #include "llvm/Target/TargetMachine.h" using namespace llvm; namespace { struct InstrumentationOptions { // Whether to emit PATCHABLE_TAIL_CALL. bool HandleTailcall; // Whether to emit PATCHABLE_RET/PATCHABLE_FUNCTION_EXIT for all forms of // return, e.g. conditional return. bool HandleAllReturns; }; struct XRayInstrumentation : public MachineFunctionPass { static char ID; XRayInstrumentation() : MachineFunctionPass(ID) { initializeXRayInstrumentationPass(*PassRegistry::getPassRegistry()); } void getAnalysisUsage(AnalysisUsage &AU) const override { AU.setPreservesCFG(); AU.addPreserved(); AU.addPreserved(); MachineFunctionPass::getAnalysisUsage(AU); } bool runOnMachineFunction(MachineFunction &MF) override; private: // Replace the original RET instruction with the exit sled code ("patchable // ret" pseudo-instruction), so that at runtime XRay can replace the sled // with a code jumping to XRay trampoline, which calls the tracing handler // and, in the end, issues the RET instruction. // This is the approach to go on CPUs which have a single RET instruction, // like x86/x86_64. void replaceRetWithPatchableRet(MachineFunction &MF, const TargetInstrInfo *TII, InstrumentationOptions); // Prepend the original return instruction with the exit sled code ("patchable // function exit" pseudo-instruction), preserving the original return // instruction just after the exit sled code. // This is the approach to go on CPUs which have multiple options for the // return instruction, like ARM. For such CPUs we can't just jump into the // XRay trampoline and issue a single return instruction there. We rather // have to call the trampoline and return from it to the original return // instruction of the function being instrumented. void prependRetWithPatchableExit(MachineFunction &MF, const TargetInstrInfo *TII, InstrumentationOptions); }; } // end anonymous namespace void XRayInstrumentation::replaceRetWithPatchableRet( MachineFunction &MF, const TargetInstrInfo *TII, InstrumentationOptions op) { // We look for *all* terminators and returns, then replace those with // PATCHABLE_RET instructions. SmallVector Terminators; for (auto &MBB : MF) { for (auto &T : MBB.terminators()) { unsigned Opc = 0; if (T.isReturn() && (op.HandleAllReturns || T.getOpcode() == TII->getReturnOpcode())) { // Replace return instructions with: // PATCHABLE_RET , ... Opc = TargetOpcode::PATCHABLE_RET; } if (TII->isTailCall(T) && op.HandleTailcall) { // Treat the tail call as a return instruction, which has a // different-looking sled than the normal return case. Opc = TargetOpcode::PATCHABLE_TAIL_CALL; } if (Opc != 0) { auto MIB = BuildMI(MBB, T, T.getDebugLoc(), TII->get(Opc)) .addImm(T.getOpcode()); for (auto &MO : T.operands()) MIB.add(MO); Terminators.push_back(&T); if (T.shouldUpdateCallSiteInfo()) MF.eraseCallSiteInfo(&T); } } } for (auto &I : Terminators) I->eraseFromParent(); } void XRayInstrumentation::prependRetWithPatchableExit( MachineFunction &MF, const TargetInstrInfo *TII, InstrumentationOptions op) { for (auto &MBB : MF) for (auto &T : MBB.terminators()) { unsigned Opc = 0; if (T.isReturn() && (op.HandleAllReturns || T.getOpcode() == TII->getReturnOpcode())) { Opc = TargetOpcode::PATCHABLE_FUNCTION_EXIT; } if (TII->isTailCall(T) && op.HandleTailcall) { Opc = TargetOpcode::PATCHABLE_TAIL_CALL; } if (Opc != 0) { // Prepend the return instruction with PATCHABLE_FUNCTION_EXIT or // PATCHABLE_TAIL_CALL . BuildMI(MBB, T, T.getDebugLoc(), TII->get(Opc)); } } } bool XRayInstrumentation::runOnMachineFunction(MachineFunction &MF) { auto &F = MF.getFunction(); auto InstrAttr = F.getFnAttribute("function-instrument"); bool AlwaysInstrument = InstrAttr.isStringAttribute() && InstrAttr.getValueAsString() == "xray-always"; bool NeverInstrument = InstrAttr.isStringAttribute() && InstrAttr.getValueAsString() == "xray-never"; if (NeverInstrument && !AlwaysInstrument) return false; auto ThresholdAttr = F.getFnAttribute("xray-instruction-threshold"); auto IgnoreLoopsAttr = F.getFnAttribute("xray-ignore-loops"); unsigned int XRayThreshold = 0; if (!AlwaysInstrument) { if (!ThresholdAttr.isStringAttribute()) return false; // XRay threshold attribute not found. if (ThresholdAttr.getValueAsString().getAsInteger(10, XRayThreshold)) return false; // Invalid value for threshold. bool IgnoreLoops = IgnoreLoopsAttr.isValid(); // Count the number of MachineInstr`s in MachineFunction int64_t MICount = 0; for (const auto &MBB : MF) MICount += MBB.size(); bool TooFewInstrs = MICount < XRayThreshold; if (!IgnoreLoops) { // Get MachineDominatorTree or compute it on the fly if it's unavailable auto *MDT = getAnalysisIfAvailable(); MachineDominatorTree ComputedMDT; if (!MDT) { ComputedMDT.getBase().recalculate(MF); MDT = &ComputedMDT; } // Get MachineLoopInfo or compute it on the fly if it's unavailable auto *MLI = getAnalysisIfAvailable(); MachineLoopInfo ComputedMLI; if (!MLI) { ComputedMLI.getBase().analyze(MDT->getBase()); MLI = &ComputedMLI; } // Check if we have a loop. // FIXME: Maybe make this smarter, and see whether the loops are dependent // on inputs or side-effects? if (MLI->empty() && TooFewInstrs) return false; // Function is too small and has no loops. } else if (TooFewInstrs) { // Function is too small return false; } } // We look for the first non-empty MachineBasicBlock, so that we can insert // the function instrumentation in the appropriate place. auto MBI = llvm::find_if( MF, [&](const MachineBasicBlock &MBB) { return !MBB.empty(); }); if (MBI == MF.end()) return false; // The function is empty. auto *TII = MF.getSubtarget().getInstrInfo(); auto &FirstMBB = *MBI; auto &FirstMI = *FirstMBB.begin(); if (!MF.getSubtarget().isXRaySupported()) { FirstMI.emitError("An attempt to perform XRay instrumentation for an" " unsupported target."); return false; } if (!F.hasFnAttribute("xray-skip-entry")) { // First, insert an PATCHABLE_FUNCTION_ENTER as the first instruction of the // MachineFunction. BuildMI(FirstMBB, FirstMI, FirstMI.getDebugLoc(), TII->get(TargetOpcode::PATCHABLE_FUNCTION_ENTER)); } if (!F.hasFnAttribute("xray-skip-exit")) { switch (MF.getTarget().getTargetTriple().getArch()) { case Triple::ArchType::arm: case Triple::ArchType::thumb: case Triple::ArchType::aarch64: case Triple::ArchType::mips: case Triple::ArchType::mipsel: case Triple::ArchType::mips64: case Triple::ArchType::mips64el: { // For the architectures which don't have a single return instruction InstrumentationOptions op; op.HandleTailcall = false; op.HandleAllReturns = true; prependRetWithPatchableExit(MF, TII, op); break; } case Triple::ArchType::ppc64le: { // PPC has conditional returns. Turn them into branch and plain returns. InstrumentationOptions op; op.HandleTailcall = false; op.HandleAllReturns = true; replaceRetWithPatchableRet(MF, TII, op); break; } default: { // For the architectures that have a single return instruction (such as // RETQ on x86_64). InstrumentationOptions op; op.HandleTailcall = true; op.HandleAllReturns = false; replaceRetWithPatchableRet(MF, TII, op); break; } } } return true; } char XRayInstrumentation::ID = 0; char &llvm::XRayInstrumentationID = XRayInstrumentation::ID; INITIALIZE_PASS_BEGIN(XRayInstrumentation, "xray-instrumentation", "Insert XRay ops", false, false) INITIALIZE_PASS_DEPENDENCY(MachineLoopInfo) INITIALIZE_PASS_END(XRayInstrumentation, "xray-instrumentation", "Insert XRay ops", false, false)